Центробежные вентиляторы дымоудаления BKF

Центробежные вентиляторы дымоудаления BKF

BKF radial fans are suitable for extraction of hot smoke gases (F400, 2h) as well

as for daily ventilation up to 120°C media.

Casing

The casing is manufactured from ZM (Zinc-Magnesium) coated steel.

Motor

IEC flange motors outside air stream with efficiency class IE2, where applicable.

Impeller geometry

Radial impeller with backward curved blades manufactured from steel.

Output control

Speed controllable via frequency converter.

Motor protection

Integrated PTC thermistors

Dual purpose fans: normal ventilation plus smoke and heat extract

• 400°C/120 min (F400)
• Continuous operation up to 120°C media
• Casing made of zinc-magnesium coated steel (ZM)
• Backward curved impeller made from pre-galvanized steel or from steel and galvanized
• Motor outside the air stream
• Single speed IE2 motors (IE1 exceptions at some items up to 0,55 kW and 8 pole) rsp. two speed motors
• PTC serial built-in motor
• Certified according EN 12101-3 by BSI
• Installation possible in all positions, flange connection 30 mm
• Installation outside building or inside building, outside fire zone in well ventilated rooms

BKF smoke and heat extract fans are used in case of fire to extract smoke gases and also during normal working conditions for standard ventilation.

Smoke free escape routes assist egress and provide clear access points for fire departments. Extracting poisonous and hot gases also make fire extinguishing easier and reduce the damage on the building.

Applications: malls, garages, warehouses, kitchen exhaust...

Generally suitable for ambient temperature -20 to +40°C (depending on specific motor load the permissible ambient temperature may be increased - on request)

For speed control of single speed motors use combination of frequency converter and appropriate filter to motor side (sine or du/dt), respectively observe instructions. Not suitable for voltage control. Working points within blue area of diagrams of single speed fans can be achieved with frequency converter. Tested to 400°C/2h together with frequency converter. However, we recommend bridging of frequency converter in case of fire to eliminate possible risk of malfunction of frequency converter. In case of fire all motor protective devices and thermal protections in frequency converter must be bridged or disabled to guarantee functional capability. When choosing AES control accessory please observe serial connecting capability of the motor (instructions).

 

Технические характеристики

Цены с НДС Цены без НДС
Наименование Напряжение (номинальное) Частота Phases Схема подключения двигателя Потребляемая мощность Цена, руб
BKF 315D4-XL/F400 IE2 400 В 50 Hz 3~ Y 244 Вт 131 638
BKF 315D6-XL/F400 IE2 400 В 50 Hz 3~ Y 168 Вт 127 795
BKF 355D4/F400 IE2 400 В 50 Hz 3~ Y 328 Вт 141 032
BKF 355D6/F400 IE2 50/60Hz 400 В 50 Hz 3~ Y 156 Вт 131 821
BKF 400D4-XL/F400 IE3 400 В 50 Hz 3~ Y 589 Вт 163 968
BKF 400D4-XS/F400 IE2 400 В 50 Hz 3~ Y 444 Вт 162 809
BKF 400D6-XL/F400 IE2 400 В 50 Hz 3~ Y 271 Вт 156 465
BKF 400D6-XS/F400 IE2 400 В 50 Hz 3~ Y 211 Вт 152 927
BKF 450D4/F400 IE3 400 В 50 Hz 3~ Y 860 Вт 166 652
BKF 450D6/F400 IE2 400 В 50 Hz 3~ Y 350 Вт 157 868
Показать всё
Просмотреть полный список технических характеристик
Производитель:Systemair Страна происхождения:Швеция Цена:  требует расчета

Версия для печати
Комментарии пользователей (0)
Предварительная регистрация не требуется, заполните свои данные вручную или через соцсети:
Комментариев нет


Характеристики товаров, цены и информация, размещенная на данной странице сайта не является публичной офертой.
Перед размещением заказа уточняйте о возможных изменениях.
В случае обнаружения несоответствий технической информации, ошибок, неточностей на нашем сайте просим Вас сообщать на zakaz.vensnab@yandex.ru
Москва, 1-й Институтский проезд, дом 3
Телефон: (495) 136-26-72
E-mail: zakaz.vensnab@yandex.ru
Copyright © «ВентCнаб»®, 2008 - 2024 г. Все права защищены.