Integrated cooling module, compact AHU
• Plug in DX-Cooling unit
• Easy to install
• Factory tested, ready to run
• Inverter controlled Scroll compressor
• Unique "Soft Cooling" function
• Unique self adaption to air flow
• Easy maintenance
Topvex SoftCooler SR is a new series of cooling modules for Topvex SR, sizes 09 and 11. The modules have been developed to meet the high comfort and energy requirements and provide very simple installation and commissioning.
Complete delivery
Topvex SoftCooler is delivered as a separate unit module, factory tested and ready to operate. The module contains a complete ready for operation DX cooling system (R410A) with a speed controlled compressor.
Simple installation
Installation of the unit is very simple:
• Topvex SoftCooler is installed between the fan sections
• Power supply is connected
• Prepared internal control wiring is connected to the Topvex electric cabinet.
• Drain is connected
Due to that the unit is fully tested at the factory the commissioning is fast and safe.
SoftCooling - unique power control.
With a unique large control range of the cooling power the Topvex SoftCooler can keep the supply air temperature on a more precise level then other comparable systems. This gives a better indoor comfort in the premises. Due to that the cooling power can be adjusted against the actual need, in a better way compared to an on/off system, the system´s COP factor is positively influenced.
Integration with the control equipment
Topvex SoftCooler is supplied with complete internal wiring for quick connection to the air handling unit\'s control system. The cooler is controlled precisely after the unit\'s present settings and requirements. Alarm from Cooler is indicated in the unit\'s alarm panel.
Adapts itself to the air volume
This type of unit gives off the condenser heat to the exhaust air. The cooling output is therefore directly dependent on the current extract air volume, Topvex SoftCooler has a unique adaptation of the cooling power to the current air volume: the condensing pressure is sensed continuously via a pressure sensor. If the condensing pressure approaches the upper permitted limit (for example because of that the extract air filter is clogged), the compressor speed is automatically reduced but only so much that the condensing pressure does not exceed the upper permitted limit. The outcome is then that the pressure switch alarm can be avoided, operation is secured and the unit cools at the maximum output that the condition permits.
Ordering code.
- Model: SoftCooler SR09, SR11.
- Right or Left model: R
(Right),
L
(Left). Air direction for supply air viewed from the inspection side.
|